To generate an NBS style specification, please use the clauses listed below to complete your document.
Highlight the text you require, select copy then paste into your word processing document.
Fire Resistance of System Sound Insulation
Partition Dimensions Deflection Allowance
Heads Junctions/Corners
Fixings at Abutments Skirting/Sills
Solid Panels Finish/Colour Glazed Panels
Glazing Manifestation
Blinds Doorsets
Doorframes Doors
Vision Panels Ironmongery
Cable Management/Outlets Accessories
PRODUCT DESCRIPTION
Unilock's ‘.Signature’ is a fully relocatable 86mm thickness, modular bi-block partition system, intended for commercial use. It is available in a variety of solid panel elevations, materials and finishes, with a number of alternative doorframe configurations; plus a selection of glazing profiles, all fully interchangeable.
Designed for fast track site installation, the system consists of pre-assembled modular elements, offering the specifier the highest level of aesthetic detailing together with optimum levels of acoustic and fire performance. Tile modular elements are retained between ceiling and floor tracks incorporating a horizontal levelling facility. The system incorporates a suite of abutment and trim profiles to enable installation within standard building tolerances without cutting or scribing the modular elements.
Unilock's Signature’ features the precise detailing and construction tolerances of a factory assembled system and is ideal for use in areas subject to high churn rates where relocatability is an important factor.
FIRE RESISTANCE OF SYSTEM
The system has been designed and tested to achieve half hour fire resistance for all major elements.
Insert, for example:
• Solid steel full height FR30 panels : half hour to BS476 Part 22.
• Double glazed full height panels, fitted with ‘Pyrocet’ FR glass 6mm to unexposed face : half hour to BS476 Part 22.
• Full height classic radiused doorframe with ‘Halspan’ cored fire rated doorleaf : half hour to BS476 Part 22.
Fire rating for panels � Surface spread of flame Class O
Go to top
SOUND INSULATION
The system has been tested for acoustic performance to the procedures of ISO 140/150717.
For example:
• Solid steel panels empty cavity : 41dB.RW
• Solid steel panels, 25mm acoustic foam : 47dB.RW
• Solid steel panels, 2 x 25mm acoustic foam : 49dB.RW
• Fully glazed, 2 x 6mm glass : 39dB.RW
• Doorset, full height, solid core : 34dB.RW
Go to top
PARTITION DIMENSIONS
Solid modules, glazed and tiled modules and doorframes have a maximum floor to ceiling height capability of 3000mm. Minimum module 300mm, maximum module 1200mm for solid, 1500mm for glazed, 1000mm for single doors, 1800mm for double doors. System thickness 86mm overall.
Go to top
DEFLECTION ALLOWANCE
The system allows for +/- 7.5mm from nominal ceiling horizontal for run-out.
For example:
• Permissible ceiling run out +/- 7.5mm.
Go to top
HEADS
50mm wide headtrack, inset 18mm from partition face, 35mm expressed depth, filled with 80KG/M3 acoustic foam.
For example:
• Standard headtrack 35mm depth.
Go to top
JUNCTIONS/CORNERS
The system modules are locked together at junctions by means of a patented concealed ‘J’ Connector key. Inset between the panels is a friction fitted flush PVC insert strip of nominal 10mm width.
For example:
• Panels locked together by ‘J’ Connector key covered by 10mm PVC flush insert strip. Extruded aluminum corners are available in radiused or square profiles, to match the panel height.
• Radiused corner profile or square corner profile.
Go to top
FIXINGS AT ABUTMENTS
Fixings are typically plastic expansion plugs and steel screws into building fabric. Alternatively, double sided adhesive tape is used for a non-mechanical fixing. Specify under this clause.
Go to top
SKIRTING/SILLS
50mm basetrack, inset 18mm from partition face, 65mm expressed depth, filled with 80KG/M3 acoustic foam.
For example:
• Standard basetrack 65mm depth.
Go to top
SOLID PANELS FINISH/COLOUR
Solid panels are available with a variety of finishes : polyester powder coated steel to a minimum 50 microns, to a range of standard colours, laminate and veneered boards and fabric wrapped boards. Tile finish of the panels should be specified under this clause.
For example:
• Polyester powder coated steel panels.
Go to top
GLAZED PANELS
Glazed panels are available with a number of alternative frame profiles : Classic Radius, flush or framed Aerofoil and flush or framed Square. Tile profile of the glazing framework should be specified under this clause. All glazed module panels are interchangeable with the solid and doorset modules.
For example:
• Aerofoil flush glazed full height
• Classic Radius glazed full height
• Framed square glazed full height
• Square flush glazed full height
Go to top
GLAZING
Should be specified as 6mm toughened.
For example:
• Glass to be 6mm toughened safety glass factory glazed into glazing frames.
Go to top
MANIFESTATION
Should be specified under this clause as site applied vinyl film, acid etching, sandblasting or applied glass paint via silk screen process.
Go to top
BLINDS
Are available in the system for full height glazed classic radius.
For example:
• Glazed modules of classic radius profile to incorporate 25mm venetian blinds, blind control cable and actuator knob. Define colour of blinds under this clause.
Go to top
DOORSETS
Doorsets are available with a number of alternative frame profiles : Classic Radius, Aerofoil and Square, housing 44/54mm solid and 10/12mm glass doorleaves. Tile profile of the doorframe and the proposed doorleaf should be specified under this clause. All doorframe modules are interchangeable with solid and glazed modules.
Go to top
DOORFRAMES
Select doorframe profile.
For example:
• Classic Radius full height single/double or
• Aerofoil full height single/double or
• Square full height single/double.
Go to top
DOORS
The doorleaf thickness, material (timber/glass), surface finish and fire rating if applicable should be specified under this clause.
Go to top
VISION PANELS
The position, size, glass type framing section, should be specified under this clause.
Go to top
IRONMONGERY
All ironmongery should be specified under this clause, including closers, handles, escutcheons. Signature system doorframe incorporates a strike box suitable for single throw locks Union 2277 or similar dimensions and Royde and Tucker hi load hinges.
Go to top
CABLE MANAGEMENT/OUTLETS
The system is capable of including cutouts for switch boxes and socket outlets formed in the solid panels, or incorporated into a service pilaster of 100mm adjacent to a doorframe or panel. Tile requirements for electrical/service outlets should be specified under this clause.
For example:
• Cutouts for single/double socket outlets to be preformed in steel partition panels.
Location to be identified
Go to top
ACCESSORIES
Racking strips for insertion into modular junctions to support shelving should be specified under this clause.
Go to top