To generate an NBS style specification, please use the clauses listed below to complete your document.

Highlight the text you require, select copy then paste into your word processing document.

 

Fire Resistance of System                             Sound Insulation
Partition Dimensions                                  Deflection Allowance
Heads                                                               Framing
Junctions/Corners                                     Fixings at Abutments
Skirting/Sills                                        Solid Panels Finish/Colour
Glazed Panels                                            Glass Types
Manifestation                                                  Blinds
Doorsets                                                         Doorframes
Doors                                                          Vision Panels
Ironmongery                                        Cable Management/Outlets
Accessories


PRODUCT DESCRIPTION

Unilock 'Mistral' is a demountable 80mm thickness composite partition system, intended for commercial use. It comprises pre-decorated gypsum board panels mounted onto a framework of vertical galvanised studs, located within ceiling and floor tracks, retained by means of Omega section metal trims screw fixed in position. It is available with a number of alternative doorframe configurations and single and double glazed elevations.

A double skinned 'Soundwall' 100mm variant with enhanced acoustic properties can be integrated within the Mistral construction, as can 'Stratus' monolithic finishes in place of the Omega section at module joints and 'Flushwall' V-joint junctions.

The system incorporates a number of head and base track variations to provide a range of aesthetic options for the specifier and is capable of accommodating various acoustic infill media to provide a range of acoustic performances.


FIRE RESISTANCE OF SYSTEM

The system has been designed and tested to achieve half hour fire resistance for all major elements.

For example:

• Full height gypsum FR30 panels: half hour to BS476 Part 22.
• Double glazed full height panels, fitted with 'Pyrocet' fire resisting glass to unexposed face: half hour to BS476 Part 22.
• Full height classic radiused doorframe with "Halspan' cored fire rated doorleaf: half hour to BS476 Part 22.
Go to top

SOUND INSULATION

The system had been tested for acoustic performance to the procedures of ISO 140/ISO717.

Mistral variant.
For example:

• Solid gypsum panels, empty cavity: 37dB.RW
• Solid gypsum panels, 25mm glassfibre blanket 16KG/M3 : 43dB.RW
• Solid gypsum panel 40mm rockwool 60KG/M3 : 46dB.RW

Flushwall variant.
For example:

• Solid gypsum panels, empty cavity : 38dB.RW
• Solid gypsum panels, 25mm glassfibre blanket 16KG/M3 : 45dB.RW
• Solid gypsum panels 40mm rockwool 60KG/M3 : 46dB.RW

Soundwall variant.
Insert, for example:

• Solid gypsum panels, 25mm glassfibre blanket 16KG/M3 : 47dB.RW
• Solid gypsum panels 40mm rockwool 60KG/M3 : 49dB.RW
Go to top

PARTITION DIMENSIONS

Solid modules, glazed and tiled modules and doorframes have a maximum floor to ceiling height capability of 3000mm. Standard panel module 1213mm for Mistral and Soundwall variant, 1200mm for Flushwall and Stratus variant. Maximum door module 1000mm for single and 1800mm for double. System thickness 80mm overall for Mistral and Stratus/Flushwall, 100mm overall for Soundwall.
Go to top

DEFLECTION ALLOWANCE

The system follows the line ceiling and compensates for ceiling run out.


HEADS

Several options of headtrack can be specified under this clause; flush standard 25mm deep steel headtrack or 35mm deep aluminium recessed headtrack, inset 15mm from partition face.

For example:

• Standard flush headtrack 25mm depth or
• Recessed headtrack 35mm depth.
Go to top

FRAMING

The framing elements are of cold rolled galvanised steel, with exposed sections polyester powder coated.

For example:

• Framework of rolled steel components, polyester powder coated to exposed surfaces, stud nominal dimensions 50 x 38.
Go to top

JUNCTIONS/CORNERS

The system panel junctions comprise of a 36mm width Omega profile with a flush PVC infill strip to conceal fixings (Mistral/Soundwall variants) and a shallow v-joint between abutting gypsum boards (Flushwall variant).

For example:

• 36mm Omega junction strip with flush PVC infill strip 8mm wide or
• v-joint to gypsum board junctions.

Extruded aluminium corners are available in radiused or square profile, floor to ceiling height.

For example:

• Radiused corner profile or
• Square corner profile.
Go to top

FIXINGS AT ABUTMENTS

Fixings are typically plastic expansion plugs and steel screws into building fabric. Alternatively, double sided adhesive tape is used for a non-mechanical fixing. Specify under this clause.
Go to top

SKIRTING/SILLS

Several options of basetrack/sills details can be specified under this clause; 55mm deep PVC clip on skirting; inset recessed base 55mm expressed depth; face fixed aluminium powder coated skirting 80mm deep.

For example:

• 55mm PVC skirting with clip on fixing or
• 55mm deep recessed base or
• 80mm aluminium skirting with concealed screws.
Go to top

SOLID PANELS FINISH/COLOUR

Solid panels are available factory finished with sheet vinyl or fabric. Exposed metal components and trims are finished with polyester powder coating to a minimum of 50 microns. Tile finish of the panels and trims should be specified under this clause.
Go to top

GLAZED PANELS

Glazed panels are available in single or double glazing, site glazed. The glass is installed flush to the face of the partitions in both variants, held by the same Omega profile as solid elevations, presenting the same junction appearance. All glazed module constructions are interchangeable with the solid modules of the same dimensions.

For example:

• Double glazed full height or
• Single glazed full height.
Go to top


GLASS TYPES

Should be specified as 6mm toughened.

For example:

• Glass to be 6mm toughenes safety glass, with round edges for safe handling on site, glazed into prepared frameworks.
Go to top

MANIFESTATION

Should be specified under this clause as site applied vinyl film, acid etching, sandblasting or applied glass paint via silk screen process.
Go to top

BLINDS

Blinds are incorporated within the system in single glazed or double glazed format.

For example:

• Glazed modules of Mistral to incorporate 25mm venetian blinds, blind control cable and actuator knob. Define colour of blinds under this clause.
Go to top

DOORSETS

Doorsets are available full height or standard 2100mm height with a number of alternative frame profiles: Classic Radius, Aerofoil and Square, housing 44/54mm solid and 10/12mm glass doorleaves. The profile of the doorframe and the proposed doorleaf should be specified under this clause. All doorframe modules are interchangeable with solid and glazed modules of the same modular dimension.
Go to top

DOORFRAMES

Select doorframe profile.

For example:

• Classic Radius full height single/double or
• Aerofoil full height single/double or
• Square full height single/double.
Go to top

DOORS

The doorleaf thickness, material (timber/glass), surface finish and fire rating if applicable should be specified under this clause. Door leaf should be selected from fire rated door blanks proven to perform in partition systems.
Go to top

VISION PANELS

The position, size, glass type framing section, should be specified under this clause.
Go to top

IRONMONGERY

All ironmongery should be specified under this clause, including closers, handles, escutcheons. Mistral system doorframes incorporate a strike box suitable for single throw locks Union 2277 or similar dimensions and Royde and Tucker hi load hinges.
Go to top

CABLE MANAGEMENT/OUTLETS

The system is capable of including cutouts for switch boxes and socket outlets formed in the solid panels. The requirements for electrical/service outlets should be specified under this clause.

For example:

• Cutouts for single/double socket outlets to be formed in gypsum partition panels.
Location to be identified.
Go to top


ACCESSORIES

Racking strips for insertion into partition junctions, replacing the PVC infill strips to support shelving should be specified under this clause.

Go to top